Thermal Comfort |
|||||||||||||||||
Average energy consumption in office |
Summary of Ventilation functions |
Cooling load (kWh/m |
|||||||||||||||
mid nineties |
kWh/m |
Function |
minimum ventilation (odour removal, etc.) |
ventilation for structural cooling |
Air movement for colling the body |
shading coefficient |
19°C |
23°C |
27°C |
||||||||
Germany |
55 |
required |
in all occupied buildings |
mainly in hot dry conditions |
mainly in warm humid conditions |
0.3 |
245 |
170 |
100 |
||||||||
USA |
268 |
conditions |
all conditions of external temperature |
mainly in hot dry condition outside air cooler than inside air by more than 2°C |
outside air the same or cooler than inside air |
0.2 |
215 |
140 |
70 |
||||||||
Malaysia |
269 |
suitable building |
all buildings |
high internal heat capacity building |
single banked building |
0.1 |
190 |
110 |
45 |
||||||||
Singapore |
222 |
methods stack effect |
adequate for ventilation under most conditions |
adequate for cooling |
not adequate |
0.05 |
175 |
100 |
40 |
||||||||
Rio de Janeiro |
340 |
open -ings |
no special requirements |
high outlet and low inlet, each 5% of floor area |
- |
0.02 |
160 |
85 |
35 |
||||||||
Temperature reduction by ventilation |
wind pres -sure |
adequate for ventilation |
adequate but may not be available at night |
good if available |
Example of casual thermic gains |
||||||||||||
air velocity m/s |
°K (or °C) |
open -ings |
no special requirements |
follow the requirements for stack effect |
large inlet and outlet on opposite sides of building, each 20% of wall area min. |
|
output (Watt) |
||||||||||
sensible |
latent |
||||||||||||||||
0.5 |
1.45 |
mecha -nical |
not usually necessary, but extract fans may be used in kitchens. Internal WCs also require extra fans |
not necessary as stack effect will work auto-matically if outside air is cooler than inside air |
May be desirable, tans are not needed to move the air in the room not to provide air change |
People (at 25°C DBT) - sitting - light work - heavy work |
70 90 115 |
45 140 310 |
|||||||||
1 |
2 |
typical requi rement |
1 air change per hour |
10 air changes per hour |
1-1.5m/s air speed 5equivalent to 100 air changes /hour |
Lighting (400lux) - tungstene - fluorescent - flur. 300lx + task light |
/m 50-90 15-20 5-10 |
0 0 0 |
|||||||||
1.5 |
2.5 |
|
|
|
|
Coffee urn 14litres Deep fryer 13kgs |
700 1100 |
500 1700 |
|||||||||
2 |
2.9 |
|
|
|
|
Computing terminal photocopiers Electric typewriter |
250 |
0 |
|||||||||
2.5 |
3.2 |
|
|
|
|
Dressing steriliser Bunsen burner |
2800 300 |
2600 100 |
|||||||||
Heating Home Needs |
|||||||||||||||||
|
Needs |
80' appt |
80' restored appt |
First plant iso2000 appt |
80' house |
80' restored house |
First plant iso2000 house |
||||||||||
Prod. |
central wind electricity |
7.7 MWh |
4.88 |
4.3 |
11.56 |
7.6 |
7.2 |
||||||||||
Prod. |
central electricity |
9.0 MWh |
5.7 |
5.03 |
13.51 |
8.88 |
8.42 |
||||||||||
Indiv. heat. |
methane gas |
30.1 MWh |
19.08 |
16.81 |
45.19 |
29.71 |
28.15 |
||||||||||
Indiv. heat. |
propane gas |
1002 m3 |
635.03 |
559.56 |
1504.3 |
988.99 |
936.94 |
||||||||||
Indiv. heat. |
domestic fuel |
852m3 |
539.97 |
475.79 |
1279.11 |
840.94 |
796.68 |
||||||||||
Indiv. heat. |
pinewood |
2. 88t |
1.83 |
1.61 |
4.32 |
2.84 |
2.69 |
||||||||||
Indiv. heat. |
deciduous wood |
3.22t |
2.04 |
1.8 |
4.83 |
3.18 |
3.01 |
||||||||||
Indiv. heat. |
wood pellet |
3.32t |
2.1 |
1.85 |
4.98 |
3.28 |
3.1 |
||||||||||
Air Conditionning Home Needs Cold |
Air Conditionning Home Needs Heat |
||||||||||||||||
Device |
performance |
mean |
Device |
performance |
mean |
||||||||||||
monoblock mobile |
> 2.6 kWh |
2.3 ±0.1 |
monoblock mobile |
> 3 kWh |
2.7±0.1 |
||||||||||||
monoblack fixed |
> 3 |
2.7 ±0.1 |
monoblack fixed |
> 3.4 |
31±0.1 |
||||||||||||
split & multisplit |
> 3.2 |
2.9 ±0.1 |
split & multisplit |
> 3.6 |
3.3 ±0.1 |
||||||||||||
|
Energetic Category of Equipment (Europe) |
||||||||||||||||
Thermal Home Conditioning example |
Primary Energy Consumption category |
Greenhouse gas effect |
|||||||||||||||
|
year cost |
period renewal |
kWh/ m2.year kg |
eq CO2 / m2.year |
|||||||||||||
Equipment multisplit total |
520 |
10 |
A |
< 5 |
< 5 |
||||||||||||
year maintenance (1 visit) |
140 |
10 |
B |
51 - 90 |
6 - 10 |
||||||||||||
filter replacement |
70 |
10 |
C |
91 - 150 |
11 - 20 |
||||||||||||
refrigeration fluid recharge |
70 |
10 |
D |
151 - 230 |
11 - 35 |
||||||||||||
electricity |
|
|
E |
231 - 330 |
36 - 55 |
||||||||||||
500hours year consumption |
145 |
10 |
F |
331 - 450 |
56 - 80 |
||||||||||||
Total year cost |
945 |
10 |
G |
> 450 |
> 80 |
||||||||||||
fresh produced /year |
2475 kWh |
|
|