Reinforcing Steel Concrete Cover (nfm) Roofing systems are exposed to the full brunt of the weather and can leak or fail prematurely if not properly designed, installed, and maintained. Leakage can be costly and adversely affect the functions within the building. Since modern roofing systems contain considerable thermal insulation, moisture intrusion lowers thermal efficiency and hinders energy conservation. Wet materials support fungus or mildew and can emit odors leading to sick buildings and occupants. There are two starting points in structural design. Further, with an occupied building, construction noises, fumes, fire hazards, and roof access all take on increased importance. |
||||||||||||||
Location |
cast in place |
concrete type pre cast |
pre stressed |
|||||||||||
Exposed to the weather |
75mm |
51mm |
51mm |
|||||||||||
Interior beams and columns (to ties) |
51mm |
51mm |
51mm |
|||||||||||
Interior walls and slabs |
25mm |
25mm |
25 - 38mm |
|||||||||||
slabs on grad (wire fabric) |
13mm thickness of slab but not less than 25mm |
|||||||||||||
Waterfront (3m below and 3m above mean low tide) |
75mm |
75mm |
51mm |
|||||||||||
Roofing Systems and Materials |
||||||||||||||
Roofing type |
cost range |
kg / m2 |
service life |
warranty |
UV resistance |
remarks |
||||||||
Built-up |
||||||||||||||
asphalt, base 1-2 sheet 2 plys mineral cap |
1 - 2 |
19.5 |
5 - 20 |
10 - 15 |
Good |
msot prone, because of complexity to leakage and sheet moisture entrapment |
||||||||
Fluid applied |
||||||||||||||
Acrylic elastomer w/o foam |
2-3 |
1.12 |
7 - 20 |
1 - 20 |
Good |
use on slopes 0.5:12 or greater; do not use in areas with relative humidity averaging 80-85% year. Recommend use of fast setting compounds |
||||||||
Acrylic elast. w/l in.foam |
2-3 |
2.24 |
7 - 20 |
1 - 20 |
Good |
|||||||||
polyyethane elastomer w/o foam |
4 - 5 |
1.46 |
7 - 20 |
1 - 20 |
Fair good |
moisture cured urethanes-use on slopes 0.025:12 or greater. Catalyzed urethanes - us on roof or any slope. Resistance to UV is good if top coated with aliphatic urethane |
||||||||
polyyethane elast. w/l in.foam |
4 - 5 |
2.58 |
7 - 20 |
1 - 20 |
Fair good |
|||||||||
Sheet - applied |
||||||||||||||
polyvinyl chloride (PVC) |
4-5 |
1.46 |
10-20 |
5-10 |
poor |
poor resistance to petroleum and solvents |
||||||||
ethylene propylene diene (EPDM) |
4-5 |
1.7 |
10-30+ |
10-25 |
good |
poor resistence to petroleum, most oils and plastic roof cement |
||||||||
chlorinated polyethylene (CPE) |
4-5 |
1.46 |
5 - 15 |
10 max |
fair |
poor resistance to petroleum distillates strong oxidizers, aromatic hydrocarbons |
||||||||
modified bitumen |
3-4 |
6.33 |
5 - 15 |
5 - 10 |
fair |
poor resistance to petroleum distillates, hydrocarbons, solvents & some chemicals |
||||||||
fiber reinforced cement (non abestos) |
3-5 |
19.5 - 27.3 |
30 - 50 |
30 - 50 |
good |
use on slopes 4:12 (w/o waterproofing) |
||||||||
Corrugated Metal |
||||||||||||||
aluminium |
3-4 |
2.9 |
10 |
|
good |
|
||||||||
galvanized steel |
3-4 |
8.8 |
10 |
|
good |
|
||||||||
Typical Code: Allowable Re-Roofs Over Existing Roofing |
||||||||||||||
Existing Roofing |
New Overlay Roofing |
|||||||||||||
|
Built- Up |
Shake |
Asphalt Shingle |
Tile Roof |
Metal Roof |
Modified Bitumen |
SPF |
|||||||
Slate |
NP |
NP |
NP |
NP |
NP |
NP |
NP |
|||||||
Built-Up |
Yes |
NP |
Yes (1:6) |
Yes (2.5:12) |
Yes |
Yes |
Yes |
|||||||
Asphalt Shingle |
NP |
NP |
Yes |
Yes (2.5:12) |
Yes |
Yes |
NP |
|||||||
Asphalt shingle Over Wood |
NP |
NP |
Yes |
Yes |
Yes |
Yes |
NP |
|||||||
Asphalt shingle / Asphalt shingle |
NP |
NP |
Yes |
Yes |
Yes |
Yes |
NP |
|||||||
Tile Roof |
NP |
NP |
NP |
NP |
NP |
NP |
NP |
|||||||
Metal Roof |
NP |
NP |
NP |
NP |
Yes |
NP |
Yes |
|||||||
Modified Bitumen |
Yes |
NP |
Yes |
Yes (2.5:12) |
Yes |
Yes |
Yes |