Proceed: make a hierarchy |
ICPM (A) |
power(W) |
circuits number |
Heat Burning Efficiency |
|||||||||||||||||||||
consider the future of evolving house |
25 |
5500 |
6 |
device/place |
efficiency |
|
|||||||||||||||||||
amount for the potency required |
30 |
6500 |
6 |
fireplace hood |
0.05 - 0.15 |
|
|||||||||||||||||||
think to safety (not underestimate) |
35 |
7700 |
6 |
hood & heat recycled |
0.3 -0.4 |
|
|||||||||||||||||||
mind green options |
40 |
8800 |
6 |
closed, insert |
0.4 - 0.8 |
|
|||||||||||||||||||
Equipment |
intensity (A) |
conductor section |
points (specified) |
wood stove |
0.4 - 0.8 |
|
|||||||||||||||||||
light bulb wall, ceiling |
10 |
1,5 |
5 - 12 / house |
stovemass |
0.7 - 0.9 |
|
|||||||||||||||||||
light bulb lamp & foot |
10 |
1,5 |
2 - 5 / house |
PhotoSolar Generator Assembly |
|||||||||||||||||||||
hair drier & other small devices |
15 |
4 |
1 - 3 / house |
Maximum specific Power |
131.7 |
W/m2 |
|||||||||||||||||||
TV, iron, refrigerator, vaccum cleaner |
15 |
2,5 |
2 - 4 / house |
Nominal Generator Power |
1.02 |
kWc |
|||||||||||||||||||
toaster, microwave, electric cooker |
20 - 25 |
6 mm2 |
2 - 5 / house |
Gross voltage /maximum power |
216 |
Volt |
|||||||||||||||||||
|
Temperature range of use |
-10°C to +35 |
°C |
||||||||||||||||||||||
Weight |
25 |
kgs |
|||||||||||||||||||||||
House: Mix Solar Panel and Water Heating Systems |
Heat Pump water- water |
||||||||||||||||||||||||
Hot water device |
gas |
diesel wood |
electric |
other |
from 10°C to 35°C |
||||||||||||||||||||
electric heating/water tank |
|
|
water well |
solar or geoprobe |
|||||||||||||||||||||
< 10years |
solar panel may apply without hydraulic/electric adjustment |
I |
II |
III |
I |
II |
III |
||||||||||||||||||
> 10 years |
solar panel may apply with electric adjustment |
||||||||||||||||||||||||
boiler / water tank |
|
||||||||||||||||||||||||
< 10years |
solar panel without hydraulic/electric adjust. |
|
|
heating power |
8.4 |
14.2 |
21.5 |
6.4 |
10.8 |
16.3 |
|||||||||||||||
> 10 years |
solar panel & hydraulic/mix adjust. |
|
|
input voltage |
230 400 |
230 400 |
400 |
230 |
400 |
400 |
|||||||||||||||
immediate heat (gas) |
solar panel without ... |
|
|
|
cooling power |
6.77 6.99 |
11.5 11.7 |
17.8 |
4.85 |
8.4 |
12.7 |
||||||||||||||
no water tank |
solar panel & hydraulic/ mix adjust. |
solar panel & electric adjust. |
electric power |
1.63 1.5 |
2.7 2.5 |
3.7 |
1.55 |
2.4 |
3.6 |
||||||||||||||||
Thermal Saving Conditioning Home |
perfom. coef. |
5.15 5.6 |
5.26 5.68 |
5.81 |
4.13 |
4.5 |
4.53 |
||||||||||||||||||
|
year cost |
period renewal |
Solar Ondulattor technical value example |
||||||||||||||||||||||
Equipment |
multisplit total |
520 |
10 |
|
ondulator 1 |
ondulator 2 |
|||||||||||||||||||
year maintenance (1 visit) |
140 |
|
generator power |
1.25Kwc |
3.45 |
||||||||||||||||||||
filter replacement |
70 |
|
output nominal power |
0.85 |
2.2 |
||||||||||||||||||||
refrigeration fluid recharge |
70 |
|
input voltage |
125 - 250 |
275 - 550 |
||||||||||||||||||||
Electricity |
500hours year consumption |
145 |
|
output voltage |
196 - 253 |
||||||||||||||||||||
|
total year cost |
945 |
|
output frequency |
49.8 - 50.2 |
||||||||||||||||||||
|
cool air produced /year |
2475 kWh |
|
maximum efficiency |
0.93 |
||||||||||||||||||||
|
Houseold year electricity consumption 21 developped countries 2500 kWh / inhabitant |
IP norm protection |
IP 65 |
||||||||||||||||||||||
dimensions (m) |
3.2 x 2.9 x 1.8 |
4.3 x 2.9 x 2.1 |
|||||||||||||||||||||||
Solar Collectors Accumulators |
mass |
18.5 |
34 |
||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
power in accumulators |
1kWc |
3kWc |
ratio (stocked/captors |
6.1 |
7.6 |
||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
power in captor |
6.1Kwh |
22.8 kWh |
accumulators refill autonomy 4kWh/d |
1.5 |
5.7 |
||||||||||||||||||||
stocked in accumulator |
127.2 |
474.5 |
accumula -tors refill autonomy 3kWh/d |
2 |
7.6 |