main index

P00: frame around

P01: olicognography

P03: infrastructures

wayout:contact

Registers of application docs

*drawings *

buildtype

*text *

const.design

Similar user docs

checkbuild.

healthstr.anthr

*text*

*graph*

Anthropometric Space Coefficients (not complete, suggest) first column: the place (building type), then left to right, take each 3 cells as one segment (concept/unit/value)

Ware- house

water

l/m2. day

0.15
















Cafeteria

kitchen

m2/ seat

1.12

dining

m2/ bench. person

1.02

dining room

m2/ seat

1.4










Restau- rant

kitchen restaurant cantina

m2/ seat

0.84

diningroom restaurant cantina

m2/ seat

1.5

shared lavatories

number

3

area of kitchen

m2/ served meal

0.5 - 0.25







Local Shop

all space

m2


water

l/m2.day

0.5

cons. electr Rio de Janeiro

kWh /m2

213










Concrete

dry sand

kg / m3 of con -crete

700

gravel

kg / m3.concrete

1190

water

l / m3.concrete

178

concrete

kg / m3 concrete. (8 bols.)

335







Built wall

width

m3

0.2

sand

20 l bucket

2. 20

clay

20 l bucket

1.1

water

botes 20 litros

1.1

asphalt

20 l bucket

0.25




school

teachers room

m2

20

water

l / student.day

16

density

pupils / classroom planned

25

kitchen school- camp

m2/ seat

0.65







school

density

pupil/desk

1.5

space for ampliation

%

0.27

density

pupils / classroom

27.8

primary school matricula

%

0.85







school

dining place in school-

camp

m2/ seat

1.02

pupil/

teacher

number

36

pupil / cook

number

60

pupil/ admini- strator

number

250







Profes- sional school

total built

m2/post

30

volumen edif.

m3 / post

200

constructed

m2/post

15

free space

m2 /post

30

size

average post

225

pupil/ teacher

number

18

Technical school

total built

m2/post

10

volumen edif.

m3 / post

35

constructed

m2/post

4.25

free space

m2/post

30

size

average post

1250




Industrial Space

all space

m2


water

l/ 8hrs work

27.5

energy saving goal in laboratory

MJ / m2 .year

280

energy saving goal in laboratory

MJ / m2 / poryear

160

air conditi- oning energy

electric need kW / ton. air 7-14°C

0.9




Industrial Space

work with air con- ditioning

hours /day

5

current air.19°C shad.coef. 2%

kWhours / m2

160

current air.23°C shad.coef. 2%

kW hours / m2

90










Leisure space

neighbor- hood park

m2 /inha- bitant

1.7

green space

m2 /inhabitant

2

play field 1-5 years

m2/inhabitant

0.8

playfield 6 -10 years

m2/inha- bitant

0.65

playfield 11 -15 years

m2/inha- bitant

0.4

training area

m2/ inhabi- tant

2.6

Leisure space

center minimum cover

ha

0.4

center minimum cover

ha park

0.8

roofed center & minimum out door space

ha

0.8

center covered and minimum free air

ha park

0.8

standard sports center

ha

9.8

park

hectarea

1.2

Gas station

structure

m2 /inha -bitant

0.1

space for ducts & pipes

ha/m duct or pipe

113













Kinder- garden

kinder- garden

m2 /inha- bitant

0.25

pre- school

m2 /inha- bitant

0.65

primary school

m2 /inhabitant

2

lavatories children

m2

10







Kinder- garden

room

m2

55

class- room

m2

75

density

pupils / room

40

girls lavatories

m2

15







Hotel

rooms

m2 /room

60

shared lavatories

number each 2 floors

3

kitchen

m2

30

dressing room

number / room

1







Hotel

guard- robe / room

m2

1

parks

number / inhabitant

1.1

cuartos

m2


air con- ditioning - tropics

tons of air

0.85







Hotel

living room

m2 /room

6

lavatories

m2

7

eating room

m2

50

dressing room

m2

20







Hotel

Office

m2

30

laundery

m2 / inha -bitant

1.1

parks

m2 / inhabitant

18

air con- ditioning - tropics

kW / t. air condi- tioning

0.90







Small Hotel

room

number

10

shared lavatories

number

3

kitchen

m2

30

guard robe

number

10







Small Hotel

ware- house

m2

10

parks

number

10

rooms

m2

20

built / area total

coeficient

1.3







Small Hotel

room

m2

500

toilets

m2

6

eating room

m2

30

guard robe

m2

20







Small Hotel

Office

m2

10

laundary

m2

10

parks

m2

160

water

l / inha -bitant

130







Laundery

water

l/ma- chine. day

500
















Electric lines

space for ducts & pipes

ha/ duct m

0.08

energy saving laboratory

MJ / m2.year














Market

lavatories

m2

20

damp room

m2

20

damp room or space

m2

10










Office

all space

m2

50

water

m3 / m2.year

1.33

oil saving goal

MJ / m2 / poryear

175

cons. electr Rio of Janeiro

kWh /m2

519







Office

electricity saving goal

MJ / m2 / year

100

air con- ditioning volume

tons of air for 7-14°C

0.85

current alter.19°C coef. shade 30%

kWhours / m2

250

current- alter.

23°C coef.shade 30%

kWhours / m2

170







Theater

seats

m2 /seat

2

water

l/ seat

5













Places of use docs

buildingenergy

urb.coeff

*text*

*graph*